Posted in

Can brass busbars be used in control cabinets?

When I first started working as a brass busbars supplier, I used to get a lot of confused questions from electricians and control cabinet designers alike. One of the most common? “Wait—brass? For control cabinets? I thought copper was the only metal that made sense here.” It’s a fair assumption. Copper has long been the go-to for power distribution, with its reputation for unmatched conductivity, so brass feels like an afterthought. But over the past 12 years of working directly with fabricators who build control cabinets for everything from industrial assembly lines to renewable energy setups, I’ve seen brass busbars hold their own in ways even seasoned engineers don’t always expect. Today, I want to break that down: can brass busbars actually work in control cabinets, and when you might want to reach for them instead of copper. Brass Busbars

First, let’s start with what control cabinets actually need from a busbar. These aren’t just metal strips to connect wires—they’re the nervous system of the cabinet. They carry high currents to motors, sensors, and power supplies, so they need to handle electrical load, resist corrosion, fit into tight spaces, and last for decades, often in harsh environments. The big three non-negotiables for any control cabinet busbar are conductivity, mechanical stability, and resistance to the conditions the cabinet will face. Most people judge brass right off the bat because copper has a higher electrical conductivity—pure copper clocks in at around 58 MS/m, while yellow brass (the most common type we supply) is roughly 26 MS/m. That’s almost half, so at first glance, it seems like a non-starter. But here’s the catch for control cabinets: you don’t always need that maximum conductivity, and the tradeoffs brass brings fix some of copper’s biggest pain points in these applications.

Let’s talk about the biggest win for brass in control cabinets: corrosion resistance. I’ve seen too many copper busbars in industrial cabinets fail prematurely, especially in facilities that run around the clock, have high humidity, or are exposed to dust, salt, or chemical residues. A food processing plant I worked with a few years back had their control cabinets near a washdown area—copper busbars started developing green patina within three years, which increased resistance enough to cause voltage drops and trigger unnecessary motor shutdowns. Brass, which is an alloy of copper and zinc, forms a very different protective layer. Instead of that porous green copper oxide, zinc in the brass reacts with oxygen and moisture to form a hard, tight zinc carbonate layer that sticks to the surface. That patina doesn’t flake off, doesn’t create resistance, and stops corrosion from getting deeper. We supply brass busbars with a standard tin plate too, which adds another layer of protection—perfect for cabinets in automotive factories where metal shavings and coolant mist are constant issues, or even in coastal settings where salt air accelerates copper’s decay.

Then there’s mechanical strength. Control cabinets have a lot of components crammed into small spaces. Busbars need to hold up against vibration—think of a cabinet in a packaging plant where motors are running nonstop, or a wind turbine control cabinet that’s bouncing on a tower for 20 years straight. Copper is soft, relatively malleable, so it can bend over time, especially if it’s installed with tight fasteners. I’ve had clients come to us with copper busbars that stretched or pulled loose from their connectors because of regular vibration, leading to loose connections and heat buildup. Brass is much stiffer. Our standard 1/8-inch thick brass busbar has a tensile strength of around 450 MPa, compared to pure copper’s 210 MPa. That means it holds its shape, stays tight in the mounting holes, and doesn’t deform even when the cabinet is subjected to constant vibration or changes in temperature that make metal expand and contract. For control cabinets that go into machinery that runs 24/7 with no maintenance access for years, that stiffness is a huge advantage.

Now, what about that conductivity gap? Is brass ever going to handle a 1000-amp load that copper would? Probably not—at least not without being thicker. But for most control cabinet applications, that’s not what you need. Let’s get specific: the average control cabinet for a 10-horsepower motor, which is common in small to mid-sized manufacturing, only needs a 60-amp busbar. A 1/4-inch thick brass busbar can handle that load with ease—we calculate it at roughly 85 amps for continuous use, which is more than enough. Even a 50-horsepower motor cabinet, which might need 150 amps, fits on a 3/8-inch brass busbar. The key here is that brass busbars don’t have to match copper’s size to meet the load, because their strength lets us use thinner profiles without sacrificing performance. We’ve had a medical device manufacturer switch their small control cabinets from 1/4-inch copper to 1/4-inch brass busbars, and they saved 30% on material costs because brass is less expensive per pound than copper. That’s a big win for mass-produced cabinets where every cent adds up, without losing any functionality.

Of course, brass isn’t right for every control cabinet. That’s the part I always make sure to be clear about with new customers. If you’re dealing with very high currents—over 500 amps, say, for heavy industrial equipment or large renewable energy inverters—copper will still give you a more compact busbar, since its higher conductivity means you can use a thinner strip for the same load. If your cabinet is going into an area with extremely low temperatures, like a freezer or an arctic processing plant, brass can get brittle in temperatures below -20°C, whereas copper retains its flexibility. But those are niche cases, and for the 80% of control cabinets being built today, brass checks all the other boxes better than copper.

I also want to talk about installation, because that’s something that’s often overlooked. Control cabinet builders are always looking for parts that are easy to cut, drill, and bend on-site. Copper can be tricky—if you’re cutting it with a basic tool, it can deform or leave burrs that require extra work to smooth. Brass is more machinable. Our brass busbars are milled to precise tolerances, but even if a builder needs to modify a strip on the fly, it cuts cleanly, leaves fewer burrs, and is easier to thread for mounting screws. I had a client who builds custom control cabinets for commercial buildings tell me last year that switching to brass cut their installation time per cabinet by 15%—less time sanding burrs, less time adjusting loose busbars, fewer callbacks from the field because of vibration-related connection issues. For small fabricators building 10 or 20 cabinets a month, that time savings adds up to a lot of extra money in their pocket.

Another big point: compliance and safety. Control cabinets have to meet strict industry standards, like IEC 61439 or NEC in the US, which cover things like temperature rise under load, insulation properties, and corrosion resistance. We’ve tested our brass busbars in independent labs, and they meet all the same standards as copper busbars for control cabinet use—temperature rise is within acceptable limits, corrosion resistance exceeds the required thresholds for indoor and mild outdoor applications, and their electrical performance is fully certified for low- and medium-voltage systems. That’s not to say you can just use any brass scrap—we supply C26000 yellow brass and C36000 free-machining brass, both of which are formulated specifically for electrical applications, with consistent alloy content to ensure uniform conductivity and strength. I’ve seen suppliers use cheap, low-grade brass that has impurities leading to higher resistance, but that’s not the case with the brass we work with.

Let me share a real example to make this concrete. Last year, a client who makes control cabinets for food and beverage processing came to me with a problem. Their copper busbars were failing after 18 months in washdown zones, as I mentioned earlier, costing them thousands in repairs and warranty claims. They switched to our tin-plated brass busbars two years ago, and in all their cabinets installed since then, we’ve only had one minor issue—an installation error where a fastener was too tight, which is not a material problem. Their warranty claims for control cabinet electrical parts dropped by 70%, and they’ve since switched all their production cabinets over to brass. That’s the kind of real-world proof that beats any spec sheet.

I know there’s still skepticism out there. A lot of veteran engineers cut their teeth on copper, and it’s hard to shift from what you know. But over the years, I’ve watched brass busbars go from a obscure alternative to a standard option for control cabinets, because more designers are realizing that the “perfect” busbar depends on the application, not just the metal’s name. Copper will always have its place—for high-current applications, for extreme cold environments, for cases where space is at a premium. But brass fills a gap that copper can’t: better corrosion resistance, higher strength, lower cost, easier installation, and more reliability in the conditions most control cabinets actually operate in.

If you’re in the market for busbars for control cabinets, whether you’re building custom units, doing retrofits, or designing new equipment, don’t write brass off before you look at the numbers. Calculate the load for your cabinet, check the environment it’s going into, and compare the specs. I’ve had engineers come to me thinking brass would never work, and leave with a design that saves them money and reduces maintenance long-term.

If you’re ready to discuss brass busbars for your control cabinet projects, or have questions about sizes, finishes, or compliance, I’m here to help. We work with small custom fabricators and large industrial manufacturers alike, providing custom-cut busbars tailored to your specific cabinet designs. Feel free to reach out to talk through your requirements.

Smart Protection Modules References
IEC 61439-1: Low-voltage switchgear and controlgear assemblies – Part 1: General rules
ASTM B103: Standard Specification for Busbar Brass
NEC Article 430: Motors, Motor Circuits, and Controllers


Cixi Yingda Electronics Co., Ltd.
As one of the most professional brass busbars manufacturers and suppliers in China, our products have good reputation in the market. Please rest assured to wholesale high quality brass busbars for sale here from our factory.
Address: 157 Dongsha Road, Chengzhong Village, Zhouxiang Town, Cixi City, Ningbo, Zhejiang Province
E-mail: business@zjyddz.com
WebSite: https://www.zjyddz.com/